PCR Workstation :- Sizes 2x2,3x2,4x2,6x2 and Customized

Technical Specification

Main body

Made in Mild Steel with epoxy Powder Coated Side Wall Back wall made in mild steel with Epoxy powder coated

Tray

Made in stainless steel 304 grade.Washable Primary filter positioned on top

Vibration

Low

PCR Workstation Manufacture by Imset shape
Blower Motor Assembly

Dynamically &statistically balance centrifugal blower

UV Light programming

Available with timer & UV Hour meter to avoid operator risk

IMSET PCR

Workstation reduces the risk of contamination.

Ultra violet tube light

Germicidal i.e. 254 nm Ultra violet life meter- Continuously display UV Hour on display

Provision of power

outlets for placing small micro centrifuges and vortexes inside the PCR Cabinet

Power supply

230 V ± 15%, 50 Hz ± 3%

PCR Workstation Manufacture by Imset shape
PCR Workstation Manufacture by Imset shape

Supply of HEPA filter with typical efficiency of 99.997% at 0.3 micron vertical down flow Metal Frame protected with specially designed pre-filter to increase life of HEPA

Front Sash Door

  • - Manual sliding sash door made up of imported poly carbonate sheet or toughened glass with sloping front for better access of samples
  • Front sash door height can be easily adjusted as per required by end-user.
  • The transparent sash door maximizes light & visibility inside the cabinet, providing a bright & open working environment

LCD Display

  • Digital Microprocessor Control System for Operating Fluorescent, UV Light & Blower.
  • Conveniently located display on outside of the PCR Workstation for easy use & also easy to reach from a seated working position
  • Germicidal in built Ultra violet light with 254 nm UV light to prevent cross contamination

Interlocking UV

  • The closing/opening of front door is integrated with the UV ON/OFF. The UV will automatically switch “OFF” when the sash door is opened & switch “ON” when door is closed to avoid accidental exposure of UV light to the operator.
  • Safety shield to prevent exposure to UV light, as well as the PCR Workstation as a built-in UV sterilizer.
  • Fluorescent Light positioned at front side is situated in such position to reduce operator fatigue while working
  • 10 degree slope/tilt to reduce back pain & work comfortably
  • Polycarbonate Door, Prevent accidental exposure of UV light to the operator.

Our Achivments

PCR Workstation Manufacture by Imset logo
Applicable Standards

• EN ISO 14971:2012
• EN ISO 13485 : 2012
• EN 980:2008
• EN 1041 : 2008
• EN 61010-1:2010
• EN 61326-1:2013
• EN 12469:2000

Performance Certificates

• ISO 9001 : 2015 & CE Certificate certified
• GMP Certified



  • Image 1 ACG ASSOCIATED CAPSULE PVT LTD
  • Image 2 BETHANY HOSPITAL
  • Image 3 CHITKARA UNIVERSITY
  • Image 1 HOLY SPIRIT HOSPITAL
  • Image 3 HOLY SPIRIT HOSPITAL
  • Image 1 HOMI BHABHA CANCER HOSPITAL & RESEARCH CENTER, MOHALI, PUNJAB
  • Image 2 HOMI BHABHA CANCER HOSPITAL & RESEARCH CENTER, MOHALI, PUNJAB
  • Image 3 K J SOMAIYA SUPER SPECIALITY HOSPITAL & RESEARCH CENTRE
  • Image 3 SION HOSPITAL
  • Image 3 PUNJAB UNIVERSITY
  • Image 3 IIT BOMBAY
  • Image 3 AIIMS BHOPAL
  • Image 3 BREACH CANDY HOSPITAL
  • Image 3 PATANJALI RESEARCH INSTITUTE, HARIDWAR
  • Image 2 KOLHAPUR CANCER CENTER
  • Image 3 KOLHAPUR CANCER CENTER
  • Image 3 LUPIN DIAGNOSTICS VARANASI
  • Image 1 LUPIN DIAGNOSTICS VIJAYWADA
  • Image 2 LUPIN DIAGNOSTICS VIJAYWADA
  • Image 3 SAIPRASAD MEDICARE PVT LTD